4608
Introduction
The 4608 Passive Infra-Red Detector is an indoor only dual element move-
ment detector designed for use with the 4600 control-panel, 4660/75
Multiscan, 4612-2 Channel-or 4618/9-8 Channel-Receiver.
It incorporates a dual element Infra-Red sensor with adjustable interchange-
able fresnel lenses which will give 90º wide angle vertical curtain, horizontal
curtain (pet alley) and narrow beam long range detection. The detector has
been designed to have a high signal to noise ratio and RFI immunity. The
PCB is fully ground planed to assist in reducing false alarms. A double edge
signal processing circuit is incorporated for added immunity. The 4608 is
supplied as standard with the wide angle lens.
IMPORTANT: Do not mount the unit closer than 6 inches to the ceiling, otherwise
you will not be able to remove the lid of the unit.
Technical Specification
Curtain lens 01037 UK-00.
Long range lens 01036 UK-00.
Wide angle lens 01035 UK-00.
Voltage 9 Volt Alkaline. MN 1604, 6F22, PP3.
Current 15 Microamps Quiescent (includes PIR and
Radio).
Temperature range -10º to 50º C. Humidity up to 80% (non
condensing).
Detection speed 0.2 to 3 metres per second.
Alarm period 2s open in Alarm then locked out for 2.5
minutes.
Warm up time 5 minutes from battery insertion.