System Walk Test
The user can ‘Walk Test’ the system and test the operation of each detector
circuit (with the exception of panic alarms or fire circuits) as follows:
(e) To stop the walk test and return the system to the ‘Day’ state, press the
‘Clear’ key twice.
Any circuits which are open will
be displayed in sequence. If no
circuits are open the display will
show “-- --”.
Open each detector circuit in turn.
The keypad and external sounder
will operate for each circuit
opened and the circuit number
will be shown on the display.
A
B
C
OMITday
Prog log
chime bell-test-walk
POWER
CLEAR
FAULT SERVICE OMIT
9800
1 2 3
4 5 6
7 8 9
0
(c) (d)
Enter access code. Press ‘Walk Test’ (No. 9 key).