496339 Issue 1 23 of 44
Areas. Each Area is a set of detectors in the same physical area. The 8136
can use up to eight Areas. You assign detectors to an area during program-
ming.
Levels. A Level is a group of Areas that can be set or unset at the same
time. Each Level can be thought of as a different level of security. The 8136
provides up to four Levels, labelled A, B, C and D. Each Level can have its
own Exit Mode, Entry and Exit Times, Alarm Response, and Re-Arm Re-
sponse. LEDs on the keypads show the status of each Level.
Flexi-Zone
®
. A Flexi zone is a zone type that can be used whenever you
want a zone to change type according to the Level of setting in use. Since an
Area can belong to more than one Level, and each Level can have different
entry/exit routes, then a zone with type Final Exit at one Level may need to be
a Normal Alarm at another Level. You can program a Flexi-Zone to be one of
the types Normal Alarm, Final Exit, Not Used or Entry Route for any Level in
which it appears.
Partition. A Partition is a collection of one or more Areas operating together
as an independent alarm system. The 8136 can use up to four Partitions.
Each Area can belong to only one Partition, and a Partition must have at least
one Area. You cannot program a Level to set Areas from more than one
Partition, however a user can be assigned to more than one Partition. Parti-
tions can be used to restrict access to parts of the system.
Factory Defaults
When delivered from the factory, the 8136i is preprogrammed with the
following default settings:
System Users
UO1: Name = User 01, Access Code 1234, Authority Level
A,B,C,D, System Full Use, Zone omit Permitted, Log
Access = Permitted, Change Area and Zone names =
Permitted, Change Data and Time = Permitted, Reset =
Permitted
User 02-95: Not Used (Duress=Disabled)
User 00: Name - Installer, Access Code = 7890
Installer programming
Menu 10: Account Name = No Name
Menu 20: Zone expansion = Default to whichever expander card is
fitted
Menu 30: Program zones
Menu 31: Zone Names = ZO1: Zone 001 (all other zones to Zone
[nnn])
8136 Factory Defaults