8 of 14 496334 Issue 1
Engineer Program Commands
To change: Key-in: Notes Default
Zone n 0n x y n = zone number 01 to 08
x = Zone type, one of:
0 = nu (not used) y
1 = PA (panic alarm)
2 = Fr (fire zone)
3 = Al (normal alarm)
4 = 24 (24 hour zone)
5 = FE (final exit)
6 = ER (entry route)
y = Zone attributes, any of:
7 = ch (chime)
8 = St (soak test)
9 = 2A (double knock)
B = b (armed in part set B)
C = c (armed in part set C)
OMIT = OA (omit allow)
Example: Zone 3 is a Normal Alarm, active in Part Set B and C, that is Omit Al-
lowed. Type in: 03 Zone Number
3 Normal Alarm
B Active in Part Set B
C Active in Part Set C
OMIT Omit Allow
CLEAR to store the value of the command.
Output 1 11 x y x = Output Type, one of:
0 = Bell follow
1 = Exit/entry follow
2 = Set latch type 1 Y
3 = Set latch type 2
4 = Shock sensor reset
5 = Walk test
6 = Entry system
7 = 24 hour alarm
y = Output state, one of:
8 = positive applied Y
9 = positive removed
Output 2 12 x y (as for command 11) 4 9
Engineer Code 20 nnnn Engineer code 7890
Bell Output Type 21 0 SAB, negative applied in alarm Y
1 SCB, negative removed in alarm
Loudspeaker Chime 22 1 Chime through loudspeaker & kypds Y
0 Chime through keypads only
RedCare reset † 23 0 Disabled Y
1 Enabled
Engineer Program Commands 9800